Furuno VR-5000 Vdr
VDR / SVDR

The VR-5000 is a Voyage Data Recorder (VDR) designed to meet IMO A.861 (20) and IEC 61996 regulations. The purpose of the VDR is to help investigators locate causes of marine casualty. In addition, the VDR can also be used to promote education for safe navigation.

Teklif Formu

The VR-5000 consists of a Data Collecting Unit (DCU), a Data Recording Unit (DRU), a Remote Alarm Panel (RAP) and six pieces of Microphones. The DCU contains interface modules, a powerful computer and a status monitor. It collects data from sensors as required by the IMO and IEC standards. The DCU processes the incoming data and information in the order of occurrence, while old data is overwritten with new data for storage in the DRU. The recording time is a minimum twelve hours with the standard flash memory. In case of an emergency power supply failure, the dedicated reserve batteries enable the VDR to record bridge audio for two hours The DCU is fitted with a removable hard disk for backup of data recorded in the DRU. The hot swap system and an external docking station for the removable hard disk allow data to be retrieved without interrupting the mandatory data collection. The Data Recording Unit (DRU) stores the data coming from the DCU in the flash memory. All essential navigation and status data including bridge conversation, VHF communications and radar images are recorded. The data can be retrieved by using the playback software for educational briefing as well as accident investigation purposes. The DRU components are embodied in a protective capsule. The capsule ensures survival and recovery of the recorded data after an incident. An acoustic pinger helps locate the capsule

GENERAL
Rules and Regulations
IMO A.861(20), IEC 61996, IEC 60945, IEC 61162
Data Collecting Unit (DCU)
Structure of DCU
Deck mounted, containing a status display, interface, mainframe computer, dedicated reserve battery, power supply for all VDR operation
Interface
Fire wire (IEEE1394)
1ch
Serial interface IEC 61162:
8 channels
Analog:
16 ports
Contact:
12 ports
Digital status (5-32 V):
52 ports
Bridge communication:
2ch(max6ch)
VHF audio:
2 ports
Radar RGBHV (VGA to SXGA):
1ch(max4)
Ethernet:
1 ch 10/100 Base-T
Integrity monitoring
Alarms for mains supply failure, recording function, mic function
Data retrieval
Data stored in the CPU in the DCU may be copied for lesson or investigation with an optional software. Interruption of data storage to DRU is less than 8 minutes.
Data Recording Unit (DRU)
Memory
6 GB flash memory standard for IMO mandatory data for 12 h cycle, first-in first-out basis. Retains data for more than 10 years under no external power. Larger memory for extended duty cycle (Optional)
ENVIRONMENTAL TESTS (for protective capsule)
Fire
1100°C for 1 h, 260°C for 10 h (complies with ED 56A)
Shock
50 G, duration 11 ms
Penetration
250 kg with a pin ø100 mm dropped from 3 m (ED 56A)
Deep sea immersion
6,000 m
Acoustic Pinger
Pinger emitting 10 ms pulses at 37.5 kHz. Automatically switched on when submerged in water.
Data retrieval
By playback equipment (not part of standard VR-5000)
POWER SUPPLY
115 - 230 VAC, 50 - 60 Hz
EQUIPMENT LIST
Standard
1. Data Collecting Unit (incl. Removable Hard Disk)
2. Data Recording Unit with 30 m cable and cradle
3. Microphone
4. RemoteAlarmPanel
5. Installation Materials and Spare Parts
Optional
1. Playback Software for displaying recorded data
2. Docking station for Removable Hard Disk
3. VHF Interface IF-5200